Electrochemical Instrumentation.
Model 600B Series
Electrochemical Analyzer/Workstation

|
|
| |
|
| |
Electrochemical instrumentation (Click on the model nos for more details)
Model 600D Series Potentiostat/Galvanostat
Model 700C Series Bipotentiostat
Model 800C Series Electrochemical Detector
Model 920C Scanning Electrochemical Microscope (SECM):
Model 1000D Series Multi-potentiostat
Model 1100D Power Potentiostat/Galvanostat
Model 1200D Handheld Potentiostat/Bipotentiostat
Model 1550 Pico Liter Solution Dispenser
Model 400D Series Time-Resolved Electrochemical Quartz Crystal Microbalance (EQCM)
Features
|
| |
 |
Computer Controlled |
| |
|
|
| |
 |
Windows based user friendlier software |
| |
|
|
| |
 |
Serial/USB Connectivity |
| |
|
|
| |
 |
Scan rates up to 5000 V/s |
| |
|
|
| |
 |
Cost effective best value for the money |
| |
|
|
| |
 |
Coulometry setup with Pt wire gauze electrode |
| |
|
|
| |
|
Spectroelectrochemistry option |
| |
|
|
| |
 |
Impedance, Voltammetery Corrosion & pulse techniques |
| |
|
|
| |
 |
Electrodes & Accessories |
| |
|
|
| |
Differences of 600D Series Models |
| |
Functions |
600D |
602D |
604D |
610D |
620D |
630D |
650D |
660D |
Cyclic Voltammetry (CV) |
* |
* |
* |
* |
* |
* |
* |
* |
Linear Sweep Voltammetry (LSV) & |
* |
* |
* |
* |
* |
* |
* |
* |
Staircase Voltammetry (SCV) #,& |
|
|
|
|
|
* |
* |
* |
Tafel Plot (TAFEL) |
|
* |
* |
|
|
* |
* |
* |
Chronoamperometry (CA) |
* |
* |
* |
|
* |
* |
* |
* |
Chronocoulometry (CC) |
* |
* |
* |
|
* |
* |
* |
* |
Differential Pulse Voltammetry (DPV) #,& |
|
|
|
* |
* |
* |
* |
* |
Normal Pulse Voltammetry (NPV) #,& |
|
|
|
* |
* |
* |
* |
* |
Differential Normal Pulse Voltammetry (DNPV) #,& |
|
|
|
|
|
|
|
* |
Square Wave Voltammetry (SWV) & |
|
|
|
|
* |
* |
* |
* |
AC Voltammetry (ACV) #,&,$ |
|
|
|
|
|
* |
* |
* |
2nd Harmonic AC Voltammetry (SHACV) #,&,$ |
|
|
|
|
|
* |
* |
* |
Amperometric i-t Curve (i-t) |
|
|
|
|
|
* |
* |
* |
Differential Pulse Amperometry DPA) |
|
|
|
|
|
|
|
* |
Double Differential Pulse Amperometry (DDPA) |
|
|
|
|
|
|
|
* |
Triple Pulse Amperometry (TPA) |
|
|
|
|
|
|
|
* |
Integrated
Pulse Amperometric Detection (IPAD) |
|
|
|
|
|
|
|
* |
Bulk Electrolysis with Coulometry (BE) |
* |
* |
* |
|
* |
* |
* |
* |
Sweep-Step Functions (SSF) |
|
|
|
|
|
|
* |
* |
Multi-Potential Steps (STEP) |
|
|
|
|
|
|
* |
* |
Hydrodynamic Modulation Voltammetry (HMV) |
|
|
|
|
|
|
* |
* |
AC Impedance (IMP) |
|
|
* |
|
|
|
* |
* |
Impedance - Time (IMPT) |
|
|
* |
|
|
|
* |
* |
| Impedance - Potential (IMPE) |
|
|
* |
|
|
|
* |
* |
Chronopotentiometry (CP) |
|
|
|
|
|
|
|
* |
Multi-Current
Steps (ISTEP) |
|
|
|
|
|
|
|
* |
Chronopotentiometry with Current Ramp (CPCR) |
|
|
|
|
|
|
|
* |
Potentiometric Stripping Analysis (PSA) |
|
|
|
|
|
|
|
* |
Open Circuit Potential - Time (OCPT) |
* |
* |
* |
* |
* |
* |
* |
* |
|
Galvanostat |
|
|
|
|
|
|
|
* |
RDE control (0-10V output) |
|
|
|
|
|
* |
* |
* |
Auxiliary Signal Measurement Channel |
* |
* |
* |
* |
* |
* |
* |
* |
Full version of CV simulator |
|
|
|
|
|
* |
* |
* |
Limited version of CV simulator |
* |
* |
* |
* |
* |
|
|
|
|
| |
|
|
| |
#: Corresponding polarographic mode can be performed.
&: Corresponding stripping mode can be performed.
$: Phase selective data are available. |
| |
|
| |
Hardware Specifications
|
| |
|
| |
|
Dynamic Range of Some Experimental Parameters for Model 600B Series |
| |
|
|
| |
|
Potentiostat rise time: < 1m s |
| |
|
|
| |
|
Galvanostat (660B only) |
| |
|
|
| |
|
Compliance voltage: ± 12 V |
| |
|
|
| |
|
Input impedance of reference electrode: 1012 ohm |
| |
|
|
| |
|
Minimum potential increment in CV: 100 m V |
| |
|
|
| |
|
Potential update rate: 5 MHz |
| |
|
|
| |
|
Maximum sampling rate: 2.5M Hz |
| |
|
|
| |
|
Current measurement resolution: < 1 pA |
| |
|
|
| |
|
iR compensation: positive feedback |
| |
|
|
| |
|
Automatic re-zeroing |
| |
|
|
| |
|
Cell control: purge, stir, knock |
| |
|
|
| |
|
Dimension: 12.5"(W) ´ 11"(D) ´ 4.75"(H) |
| |
|
|
| |
|
Weight: 15 Lb. |
| |
|
|
| |
|
|
| |
|
|
| |
|
Dynamic Range of Some Experimental Parameters for Model 600B Series |
|
Parameters |
Range |
Techniques |
|
Potential (V)
Current (A)
Sensitivity (A/V)
Scan rate (V/s)
Pulse width (sec)
Pulse width (sec)
Sample width (sec)
Frequency (Hz)
Frequency (Hz)
Frequency (Hz)
Frequency (Hz) |
-10 to +10
0 to ± 0.25
1´ 10-12 to 0.1
0.000001 to 5000
0.0001 to 1000
0.001 to 10
0.0001 to 10
1 to 100000
1 to 10000
1 to 5000
0.0001 to 100000 |
CV,LSV
CA, CC
DPV, NPV
DPV, NPV
SWV
ACV
SHACV
IMP
|
|
| |
|
|
| |
|
|